Produktintroduktion
This series of products are designed for use in urban power distribution networks, industrial parks, commercial buildings, subways, hospitals, and renewable energy systems. The transformer is oil-free, safe, environmentally friendly, and easy to maintain. Its insulation system is carefully treated to be moisture-proof, dust-proof, and fire-resistant, ensuring reliable operation in various environments. Yuantong focuses on energy efficiency and stable performance, and all products comply with IEC and national standards, featuring low loss, low noise, and long service life. We are committed to providing users with safe, durable, and easy-to-use power distribution equipment that delivers electricity more efficiently and reliably. The main advantages are:
- oil-free design, fire and explosion prevention, green and pollution-free;
- Hög tillförlitlighet:god mekanisk hållfasthet, starkt motstånd mot kortslutning-, motstånd mot blixtstötar, liten partiell urladdning, livslängd Större än eller lika med 30 år;
- låg förlust, lågt ljud, överbelastningskapacitet ökad med 50 %;
- Stark miljöanpassningsförmåga:fuktsäker-, dammtät, anpassningsbar till hög luftfuktighet och tuffa miljöer;
- Intelligent och lättskött:intelligent temperaturkontrollsystem, underhållsfri design;
- Enkel och ekonomisk installation:liten storlek, låg vikt, låg installationskostnad.
Grundläggande specifikationsparametrar
|
Punkt |
Specifikationsområde |
|
spänningsnivå |
10kV,20kV,35kV |
|
Nominell kapacitet |
30 kVA ~ 25000 kVA |
|
Nominell frekvens |
50 Hz |
|
Fas |
tre-fas |
|
Spänningsregleringsmetod |
icke excitationsspänningsreglering/på lastspänningsreglering |
Produktegenskaper
Vårt företags SCB10, SCB11series 10kV, 20kV och 35kV oexciterade spänningsreglerande krafttransformatorer tillhör lågförlustprodukter, som uppfyller kraven i nationella standarder GB6450, GB/T10228 och IEC726, och har följande egenskaper:
1. Hög prestanda, låg förlust;
2. Att välja högkvalitativa kallvalsade-silikonstålskivor av-kvalitet minskar kraftigt den magnetiska flödestätheten, minskar inga-lastförluster och buller;
3. Optimeringen av hög-spolstrukturen förbättrar avsevärt produktens förmåga att motstå atmosfäriska och driftsmässiga överspänningspåverkan genom att förbättra fördelningen av mellanskiktsspänning och kapacitans. Den elektriska fältfördelningen är optimerad, och den partiella urladdningen av produkten reduceras ytterligare, vilket resulterar i förbättrad isoleringsprestanda;
4. Det intelligenta temperaturkontrollsystemet och luftkylningsenheten kan konfigureras för att automatiskt starta fläktkylningsenheten när belastningen är för stor, vilket effektivt förbättrar utrustningens överbelastningstolerans och-långtidsstabilitet.
Teknisk parameter
◆20kV SC(B)10-serien excitationsreglerad distributionstransformator Prestandaparametertabell
|
Nominell kapacitet (kVA) |
Spänningskombination (kV) |
anslutnings-gruppkod |
Ingen-lastström % |
Ingen-lastförlust W |
Lastförlust W(120 grader) |
Impedans % |
||
|
(HV) kV |
Högspänningsuttagsområde % |
(LV) kV |
||||||
|
50 |
20 22 24 |
± 5 ±2x2.5 |
0.4 |
Dyn11 Yyn0 |
1.2 |
340 |
1230 |
6.0 |
|
100 |
1.1 |
535 |
1980 |
6.0 |
||||
|
160 |
1.0 |
670 |
2360 |
6.0 |
||||
|
200 |
0.8 |
730 |
2930 |
6.0 |
||||
|
250 |
0.7 |
835 |
3400 |
6.0 |
||||
|
315 |
0.6 |
960 |
4060 |
6.0 |
||||
|
400 |
0.6 |
1140 |
4820 |
6.0 |
||||
|
500 |
0.5 |
1330 |
5760 |
6.0 |
||||
|
630 |
0.5 |
1510 |
6800 |
6.0 |
||||
|
800 |
0.5 |
1730 |
8220 |
6.0 |
||||
|
1000 |
0.5 |
2040 |
9730 |
6.0 |
||||
|
1250 |
0.5 |
2360 |
11480 |
6.0 |
||||
|
1600 |
0.5 |
2760 |
13790 |
6.0 |
||||
|
2000 |
0.5 |
3200 |
16280 |
6.0 |
||||
|
2500 |
0.4 |
3820 |
19270 |
6.0 |
||||
|
3150 |
0.4 |
4300 |
23610 |
7.0 |
||||
Obs: belastningsförlusten som anges i tabellen är värdet i referenstemperaturen inom parentes (se bestämmelserna i GB1094.11).
◆ 20kV SC(B)11-serien excitationsreglerad distributionstransformator Prestandaparametertabell
|
Nominell kapacitet (kVA) |
Spänningskombination (kV) |
anslutnings-gruppkod |
Ingen-lastström % |
Ingen-lastförlust W |
Lastförlust W(120 grader) |
Impedans % |
||
|
(HV) kV |
Högspänningsuttagsområde % |
(LV) kV |
||||||
|
50 |
20 22 24 |
± 5 ±2x2.5 |
0.4 |
Dyn11 Yyn0 |
1.2 |
300 |
1230 |
6.0 |
|
100 |
1.1 |
470 |
1980 |
6.0 |
||||
|
160 |
1.0 |
580 |
2360 |
6.0 |
||||
|
200 |
0.8 |
640 |
2930 |
6.0 |
||||
|
250 |
0.8 |
720 |
3400 |
6.0 |
||||
|
315 |
0.7 |
840 |
4060 |
6.0 |
||||
|
400 |
0.6 |
1000 |
4820 |
6.0 |
||||
|
500 |
0.6 |
1170 |
5760 |
6.0 |
||||
|
630 |
0.5 |
1320 |
6800 |
6.0 |
||||
|
800 |
0.5 |
1520 |
8220 |
6.0 |
||||
|
1000 |
0.5 |
1790 |
9730 |
6.0 |
||||
|
1250 |
0.5 |
2060 |
11480 |
6.0 |
||||
|
1600 |
0.5 |
2410 |
13790 |
6.0 |
||||
|
2000 |
0.5 |
2800 |
16280 |
6.0 |
||||
|
2500 |
0.4 |
3340 |
19270 |
6.0 |
||||
Obs: Lastförlusten som anges i tabellen är värdet i referenstemperaturen inom parentes (se bestämmelserna i GB1094.11).
◆35kV SC(B) 10-serien Excitationsspänningsfördelningstransformator Prestandaparametertabell
|
Nominell kapacitet (kVA) |
Spänningskombination (kV) |
anslutnings-gruppkod |
Ingen-lastström % |
Ingen-belastningsförlust W |
Lastförlust W(120 grader) |
Impedans % |
||
|
(HV) kV |
Högspänningsuttagsområde % |
(LV) kV |
||||||
|
50 |
35 ~ 38.5 |
± 5 ±2x2.5 |
0.4 |
Dyn11 Yyn0 |
2.8 |
450 |
1430 |
6.0 |
|
100 |
2.4 |
630 |
2090 |
6.0 |
||||
|
160 |
1.8 |
790 |
2760 |
6.0 |
||||
|
200 |
1.8 |
880 |
3330 |
6.0 |
||||
|
250 |
1.6 |
990 |
3800 |
6.0 |
||||
|
315 |
1.6 |
1180 |
4510 |
6.0 |
||||
|
400 |
1.4 |
1380 |
5420 |
6.0 |
||||
|
500 |
1.4 |
1620 |
6650 |
6.0 |
||||
|
630 |
1.2 |
1860 |
7700 |
6.0 |
||||
|
800 |
1.2 |
2160 |
9120 |
6.0 |
||||
|
1000 |
1.0 |
2430 |
10450 |
6.0 |
||||
|
1250 |
0.9 |
2840 |
12730 |
6.0 |
||||
|
1600 |
0.9 |
3150 |
15490 |
6.0 |
||||
|
2000 |
0.9 |
3830 |
18240 |
6.0 |
||||
|
2500 |
0.9 |
4460 |
21850 |
6.0 |
||||
Obs: belastningsförlusten som anges i tabellen är värdet i referenstemperaturen inom parentes (se bestämmelserna i GB1094.11).
◆ 35kV SC(B)10-serien excitationsreglerad torr-Typ Power Transformers Prestandaparametertabell
|
Nominell kapacitet (kVA) |
Spänningskombination (kV) |
anslutnings-gruppkod |
Ingen-lastström % |
Ingen-belastningsförlust W |
Lastförlust W(120 grader) |
Impedans % |
||
|
(HV) kV |
Högspänningsuttagsområde % |
(LV) kV |
||||||
|
800 |
35 ~ 38.5 |
± 5 ±2x2.5 |
3.15 6 6.3 10 10.5 11 |
Dyn11 Yd11 Yyn0 |
1.1 |
2250 |
9400 |
6.0 |
|
1000 |
1.1 |
2670 |
10900 |
|||||
|
1250 |
1.0 |
3130 |
12900 |
|||||
|
1600 |
1.0 |
3690 |
15400 |
|||||
|
2000 |
0.9 |
4230 |
18200 |
7.0 |
||||
|
2500 |
0.9 |
4860 |
21800 |
|||||
|
3150 |
0.8 |
6030 |
24500 |
8.0 |
||||
|
4000 |
0.8 |
7020 |
29400 |
|||||
|
5000 |
0.7 |
8370 |
34900 |
|||||
|
6300 |
0.7 |
9900 |
40800 |
|||||
|
8000 |
Dyn11 Yd11 YNn11 |
0.6 |
11300 |
46000 |
9.0 |
|||
|
10000 |
6 6.3 10 10.5 11 |
0.6 |
12900 |
55500 |
||||
|
12500 |
0.5 |
15700 |
64600 |
|||||
|
16000 |
0.5 |
19300 |
76000 |
|||||
|
20000 |
0.4 |
22900 |
85000 |
10.0 |
||||
|
25000 |
0.35 |
27100 |
101000 |
|||||
Obs: Lastförlusten som anges i tabellen är värdet i referenstemperaturen inom parentes (se bestämmelserna i GB1094.11).
Vanliga frågor
F1: Vad är en torr transformator?
S: En torr transformator är en elektrisk transformator som använder fasta isoleringsmaterial istället för flytande, såsom olja, för att isolera mellan lindningarna och kärnan.
F2: Vad är skillnaden mellan transformatorer av torr typ och-olja?
S: Transformatorer av torr typ använder luft eller harts för isolering, vilket gör dem säkrare,-brandbeständiga och underhålls-fria, medan olje- nedsänkta transformatorer kräver olja för kylning och isolering.
F3: Vad betyder 35 års erfarenhet för transformatorer av torr-typ?
S: Det här betyder att vår design har validerats genom tusentals projekt och har samlat mogen erfarenhet inom nyckelområden som isoleringsteknik, värmeavledningsstruktur och partiell urladdningskontroll. Kunden fick en enhet som har testats över tid och som har fungerat stabilt under lång tid.
F4: Vilken är den största fördelen med transformatorer av torr-typ?
S: Säker och miljövänlig - ingen risk för oljeläckage, ingen brandrisk, underhållsfri, i enlighet med brandsäkerhetskrav. Samtidigt igång med lågt ljud, lämplig för tätbebyggda områden.
F5: Var används torra transformatorer vanligtvis?
S: De används ofta i industriella miljöer, kommersiella byggnader och inomhusapplikationer där utrymmet är begränsat och brandsäkerhet är ett problem.
F6: Är torra transformatorer dyrare än oljefyllda-?
S: Svar: Inledningsvis kan torra transformatorer vara dyrare än oljefyllda-transformatorer, men de kan ha lägre underhålls- och driftskostnader över tiden.
F7: Hur väljer man kapaciteten för transformatorer av torr-typ?
S: Baserat på den totala lasteffekten, reservera en lämplig marginal (vanligtvis vald vid 70 % -80 % av lasthastigheten), samtidigt som framtida expansionsbehov beaktas. Föreslå att tillhandahålla en lastlista för våra ingenjörer för att hjälpa till med beräkningen.
F8: Är torr-transformator bullrig?
S: Ljudnivån för konventionella produkter regleras mellan 50-65 decibel. För platser med höga bullerkrav som sjukhus och bostäder kan lågljudsdesign implementeras, med ett minimum av 45 decibel.
Populära Taggar: 10kv 20kv 35kv dry type transformers, China 10kv 20kv 35kv dry type transformers manufacturers, suppliers, factory, 10kV 20kV 35kV gjuten resin torrtransformator, 35 kV gjuten spole torrtransformator, Torrgjutna resintransformatorer, Transformator för torrresin, Torrtyptransformator, Enfasig isoleringstransformator